Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Histologic Evaluation of Threaded HA-Coated Root-Form Implants After 3.5 to 11 Years of Function: A Report of Three Cases
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 21 , Issue 1
January/February 2001

Pages 21-29


Histologic Evaluation of Threaded HA-Coated Root-Form Implants After 3.5 to 11 Years of Function: A Report of Three Cases

Periklis Proussaefs, DDS, Jaime Lozada, DDS, Mac Ojano, DDS


PMID: 11829032
DOI: 10.11607/prd.00.0399

This article presents a histologic evaluation of three hydroxyapatite (HA)-coated root-form implants retrieved from humans after being in function for 3.5 to 11 years. If the coronal portion, where bone loss was observed clinically and radiographically, is excluded, all implants appeared to be well osseointegrated, with intimate contact between the surrounding bone and the coating. There was no sign of resorption or dissolution of the HA coating. The coating had a uniform thickness (50 µm) equal to the thickness originally provided by the manufacturer. In the few areas where there was no bone contact, the HA coating appeared to line the implant with no sign of dissolution. The few detached particles had tight contact with the bone, demonstrating the biocompatibility of the HA. The observations from the three reported cases suggest that the HA coating of dental implants may not be susceptible to resorption or dissolution under long-term function. (Int J Periodontics Restorative Dent 2001;21:21–29.)


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help